TYPE
Vehicular Swing Gate Operator

CLASS OF OPERATION
Class I, II, III, IV

INPUT POWER
110-120 VAC, 60 HZ, Single Phase
5.4 Amp @ 115 VAC (typical)

MOTOR
1/2 HP 60 cycles / hr.

MOUNTING
Pad or post mounted.  Specify which at time of order.

MAXIMUM GATE WEIGHT
500 lb. (226 kg.)

MAXIMUM GATE LENGTH
14 ft. (4.3 m)

OPERATING TEMPERATURE
-140ºF - 145ºF (-40ºC - 62ºC)

SPEED
90º in approximately 10 seconds

ENTRAPMENT PROTECTION
Primary - Inherent (Type A)
Secondary - Provision for:
non-contact sensor (Type B2)

GATE RELEASE
Fail Safe - Clutch can be overridden.  A keyed release is also provided.

DIMENSIONS
Height: 11 in. (275 mm)
On pad pedestal: 21 in. (525 mm)

Width: 13.25 in. (331 mm)
Depth: 23 in. (575 mm)

WEIGHT
Approximately 110 (50 kg.) to 140 lb. (63.5 kg.) depending on mounting option selected.

LISTINGS
ETL Listed

NOTE: Use of this product is limited to vehicular swing gates only.  This product must never be used to operate any gate that is intended for pedestrian use.

Shown in pad mount configuration.

Click the image to download model 6100 Spec Sheet in PDF format.  If you do not have Acrobat Reader 4.0 or higher, click on the Acrobat icon to get a free copy.
FEATURES
bulletElectronic, automatically adjusted limit settings (no mechanical limit switches required).
bulletMechanical and electronic inherent entrapment sensing system operable in both the open and close direction.
bulletAutomatic close timer is adjustable from 1 to 23 seconds.
bulletTwo ports for plug-in loop detectors.
bulletBuilt-in reset switch.
bulletGate overlap feature starts the master operator 1-2 seconds prior to the slave operator.
bulletMagnetic lock output provided for direct connection of mag locks to the circuit board.
bulletTamper protect feature causes motor to run in the close direction if an attempt is made to force the gate open.
bulletGate Tracker™ reporting output sends gate operator data to a companion DoorKing access control system.
bulletOptional Battery Back-Up drive system opens gate automatically, or on command, during power outages